Belden Cable 1505A (Per Meter)

₹ 135.70 Sale

This 75 Ohm SDI coaxial cable (RG-59) is built for reliable digital video transmission, including HD-SDI 1080p and 6 Gb/s UHDTV. It features a solid 20 AWG bare copper conductor, foam PE insulation, and a dual-shield design (100% foil + 95% tinned copper braid) to help maintain signal integrity and reduce interference across demanding video runs.

Key Features

75 Ohm RG-59 coax for SDI video

Designed for digital video applications including HD-SDI 1080p and 6 Gb/s UHDTV workflows.

Solid 20 AWG bare copper conductor

Solid BC conductor (0.032 in nominal diameter) for stable performance in fixed installations.

Dual shielding: 100% foil + 95% tinned copper braid

Duofoil® tri-laminate tape provides full coverage, backed by a dense 95% tinned copper braid for strong noise rejection.

Low capacitance + consistent signal characteristics

Optimized electrical performance with 16.3 pF/ft capacitance, 75 Ohm impedance, and 82% velocity of propagation.

CMR rated PVC jacket for in-wall runs

PVC jacket with CMR/CMG compliance, suitable for indoor installations where riser rating is required.

Technical Specifications

Cable Type 75 Ohm SDI Coax (RG-59)
Suitable Applications Digital Video, 6 Gb/s UHDTV, HD-SDI 1080p
RG Type RG-59
Conductor Size 20 AWG
Conductor Stranding Solid
Conductor Material BC – Bare Copper
Conductor Nominal Diameter 0.032 in
Insulation Material PE – Polyethylene (Foam)
Nominal Insulation Diameter 0.145 in (3.68 mm)
Insulation Color White
Shield Layer 1 Tape (Tri-Laminate Alum+Poly+Alum) — Duofoil® — 100% coverage
Shield Layer 2 Braid — Tinned Copper (TC) — 95% coverage
Jacket Material PVC (Polyvinyl Chloride)
Overall Cable Diameter (Nominal) 0.233 in (5.92 mm)
Return Loss (Min.) 5–1600 MHz: 23 dB
1600–4500 MHz: 21 dB
4500–6000 MHz: 15 dB
Attenuation (Nominal) 1 MHz: 0.3 dB/100ft
3.58 MHz: 0.6 dB/100ft
5 MHz: 0.63 dB/100ft
6 MHz: 0.69 dB/100ft
7 MHz: 0.74 dB/100ft
10 MHz: 0.9 dB/100ft
12 MHz: 0.91 dB/100ft
25 MHz: 1.3 dB/100ft
67.5 MHz: 2.05 dB/100ft
71.5 MHz: 2.1 dB/100ft
88.5 MHz: 2.2 dB/100ft
100 MHz: 2.3 dB/100ft
135 MHz: 2.7 dB/100ft
143 MHz: 2.8 dB/100ft
180 MHz: 3.1 dB/100ft
270 MHz: 3.8 dB/100ft
360 MHz: 4.4 dB/100ft
540 MHz: 5.5 dB/100ft
720 MHz: 6.4 dB/100ft
750 MHz: 6.5 dB/100ft
1000 MHz: 7.6 dB/100ft
1500 MHz: 9.3 dB/100ft
2000 MHz: 10.9 dB/100ft
2250 MHz: 11.6 dB/100ft
3000 MHz: 13.4 dB/100ft
4500 MHz: 17.5 dB/100ft
6000 MHz: 21.1 dB/100ft
Nominal Conductor DCR 10 Ohm/1000 ft
Nominal Outer Shield DCR 3.8 Ohm/1000 ft (12 Ohm/km)
Nominal Capacitance (Cond-to-Shield) 16.3 pF/ft (53.5 pF/m)
Nominal Characteristic Impedance 75 Ohm
Nominal Velocity of Propagation 82%
UL Voltage Rating 300 V (CMR, CMG)
Temperature (UL / Operating) UL: 60°C / Operating: -30°C to +75°C
Minimum Bend Radius (Installation) 2.3 in (58 mm)
Max Pull Tension 52 lbs (24 kg)
Bulk Cable Weight 31 lbs / 1000 ft
Environmental Suitability Indoor; Indoor (Aerial – Black only, when supported by messenger wire)
Flammability / Reaction to Fire UL1666 Vertical Shaft
CPR Compliance CPR Euroclass: Eca; CPR UKCA Class: Eca
NEC / UL Compliance CMR
CEC / C(UL) Compliance CMG
European Directive Compliance EU CE Mark; EU Directive 2015/863/EU (RoHS 2 amendment); REACH; EU Directive 2011/65/EU (RoHS 2); EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance UKCA Mark
APAC Compliance China RoHS II (GB/T 26572-2011)
Plenum Number 1506A