A Genelec Smart Active Monitor for accurate professional listening and mix decisions. The 1032C combines active amplification with digital signal processing and GLM room-calibration support to help adapt monitoring to the listening space. Its detailed specifications and connections are listed below. Supplied as one monitor.
One unit.
40 Hz - 20 kHz (± 2.5 dB)
Low cutoff -6dB
33 Hz
High cutoff -6dB
23 kHz
Peak SPL
≥124 dB
Maximum peak acoustic output per pair in a listening room with music material at 1 m.
Short term max SPL
≥114 dB
Maximum short term sine wave acoustic output on axis in half space, averaged from 100 Hz to 3 kHz at 1 m.
Long term max SPL
≥104 dB
Maximum long term RMS acoustic output in the same conditions with IEC weighted noise (limited by driver protection circuit) at 1 m.
Self-generated noise
≤5 dB SPL
Self generated noise level in free space at 1 m on axis (A-weighted).
Height
495 mm
Width
320 mm
Depth
290 mm
Enclosure material
MDF
Driver type
Cone
Magnetically shielded bass driver.
Diameter
250 mm
Driver type
Metal dome
Magnetically shielded treble driver.
Diameter
25 mm
The latency at high frequencies from the input to the acoustic output, measured in the analog input:
Extended Phase Linearity in GLM set to OFF
3.2 ms
In Genelec performance graphics, the time of converting the from an electronic input signal to the acoustic output in a Genelec monitor is described by two factors – latency and group delay. The group delay factor can be read in the graphics for a specific frequency. The total frequency-specific input-to-output delay is a sum of the latency and group delay factors. To understand the significance of this total delay, consider that moving a loudspeaker away by 1 meter creates an additional delay of about 3 ms.
250 W Class D
150 W Class D
100-240 VAC 50/60Hz
ISS Active
≤1 W
Idle
≤11 W
Full output
200 W
Input
Analog signal input connector XLR female, balanced 10 kOhm.
Input
Digital signal input connector XLR female 110 Ohm.
Output
Digital signal output / Thru connector XLR male 110 Ohm.
2 x Control